Onan Start Stop
![]() |
![]() Onan 300 1579 Start Stop Universal 2 wire US $400.00
|
![]() 300 2383 ONAN WO TD START STOP MODULE MULTI LT CONT NOS US $325.00
|
![]() Onan 300 0973 TD Start Stop 24v 300 0922 YB US $324.00
|
![]() Onan 300 1059 Programmable TD Start Stop Timer ATU US $300.00
|
![]() 300 1060 ONAN 24V PROGRAMMABLE START STOP TIMER PCB NOS US $144.00
|
![]() ONAN GENSET GENERATOR START STOP SWITCH QUARTZ METER US $56.99
|
![]() GENUINE ONAN START STOP SWITCH 308 0995 US $32.59
|
![]() GENUINE ONAN START STOP SWITCH 308 1038 US $32.10
|
![]() GENUINE ONAN START STOP SWITCH 308 1050 US $29.17
|
![]() GENUINE ONAN START STOP SWITCH 308 0852 US $25.34
|
![]() GENUINE ONAN START STOP SWITCH 308 0778 US $23.54
|
![]() GENUINE ONAN START STOP SWITCH 308 1027 US $22.49
|
![]() GENUINE ONAN START STOP SWITCH 308 0826 US $16.42
|
![]() GENUINE ONAN START STOP SWITCH 308 0827 US $16.00
|
My father has a 6.5 onan generator that cranks but dies when the start button is released.?
My Father has a Onan genset that stops running when the start button is released. We have replaced the pC board with a known good one. It's getting fuel and generates as long as button is held in. Any help would be appreciated. Plenty of fuel and oil level is correct. Thanks
Oil pressure switch is bad.
There should be a single wire attatched to a round sensor on the side of the engine with a small nut.
Disconnect the wire from the pressure switch just to see if that is the problem.
Don't run it too long without replacing the switch, otherwise you could completely ruin your engine if there realy is no oil pressure.
1974 Onan 2.5AJ
You can follow any responses to this entry through the RSS 2.0 feed. Both comments and pings are currently closed.