What’s The Difference Between A Dual Stage Compressor Air Conditioner And A Single Stage
It requires basic knowledge in thermodynamics to understand the principles involved in the operation of a compressor air conditioner. One of these principles is the combined law of ideal gas which explains the relationship between the pressure, volume and temperature of the gas with a fixed mass. It states that the product of the pressure and volume of the gas is directly proportional to its volume. This means that as the temperature increases, the product of the pressure and volume also increases, and vice versa. It also means that the pressure and volume vary reversely to each other.
The compressor air conditioner primarily functions by changing the volume of the gas so that its temperature and pressure will change as well. In most cases, the gas is being compressed and forwarded to the unit’s condenser. This is where the gas cools down until it turns liquid. The liquefied gas will regain its gaseous state through the evaporator that has tiny tubing. The generated vapor is delivered back to the condenser and the sequence starts all over again.
The gas or refrigerant used in the air conditioning process is usually Freon. The low boiling point of Freon makes it suitable for many compressor air conditioners. However, there is a problem with using Freon. As it is released into the atmosphere, there is a high possibility that it will reach the ozone and causes negative effects on the environment. To get rid of this problem, many newer types of compressor air conditioners are designed with functions that prevent Freon from reaching the ozone. There are also some newer models that use refrigerants other than Freon.
One may think about the difference between dual stage and single stage compressor systems. Well, the answer lies on the pressure rating of each system. A single stage compressor air conditioner can typically compress the gas to provide a pressure of about 125 pounds per squared inch (psi). It uses aluminum tanks to handle the compressed air through the piston. A piston is the device used to exert force on the air to enable the compression. In the double stage compressor air conditioner, an additional piston is used to further compress the captured air. It results to a pressure rating that is around 50 psi higher than the single stage one. The double stage compressor air conditioners use cast iron storage tanks to support the high pressure of the air during the compression.
In choosing between the single and double stage compressor air conditioner, it is important to consider the actual level of compression needed for the application. It is also best to refer on the technical specifications sheet of both devices in order to determine the quality of its performance against your needs.If you have any other questions feel free to call the experts at HVAC Jacksonville.
HVAC Jacksonville is the only company you should call for anything related to Air Conditioning Jacksonville or Jacksonville Heating. 904-385-5790
HVAC Jacksonville 1526 University Blvd W #135 Jacksonville, FL 32217
what's the difference between a single and two stage air compressor?
You can follow any responses to this entry through the RSS 2.0 feed. Both comments and pings are currently closed.